1.
J Heart Lung Transplant ; 42(6): 707-715, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36931988

RESUMO

BACKGROUND: For normothermic ex vivo heart perfusion (EVHP), a resting mode and working mode have been proposed. We newly developed a left ventricular assist device (LVAD) mode that supports heart contraction by co-pulse synchronized LVAD. METHODS: Following resting mode during time 0 to 1 hour, pig hearts (n = 18) were perfused in either resting, working, or LVAD mode during time 1 to 5 hour, and then myocardial function was evaluated in working mode at 6 hour. The preservation ratio was defined as the myocardial mechanical function at 330 minute divided by the function at 75 minute. In LVAD mode, LVAD unloaded the pressure and the volume in the left ventricle in the systolic phase. RESULTS: The LVAD group was significantly associated with higher preservation ratios in cardiac output (resting, 33 ± 3; working, 35 ± 5; LVAD, 76% ± 5%; p < 0.001), stroke work, dP/dt maximum, and dP/dt minimum compared with the other groups. Glucose consumption was significantly reduced in the resting group. The LVAD group was significantly associated with higher myocardial oxygen consumption (resting, 2.2 ± 0.3; working; 4.6 ± 0.5; LVAD, 6.1 ± 0.5 mL O2/min/100 g, p < 0.001) and higher adenosine triphosphate (ATP) levels (resting, 1.1 ± 0.1; working, 0.7 ± 0.1; LVAD, 1.6 ± 0.2 µmol/g, p = 0.001) compared with the others. CONCLUSION: These data suggest that myocardial mechanical function was better preserved in LVAD mode than in resting and working modes. Although our data suggested similar glycolysis activity in the LVAD and working groups, the higher final ATP in the LVAD group might be explained by reduced external work in LVAD.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Suínos , Animais , Ventrículos do Coração , Função Ventricular Esquerda , Coração , Perfusão
2.
Transplantation ; 107(3): 628-638, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36476980

RESUMO

BACKGROUND: Increased extravascular lung water during ex vivo lung perfusion (EVLP) is associated with ischemia reperfusion injury and poor pulmonary function. A non-invasive technique for evaluating extravascular lung water during EVLP is desired to assess the transplant suitability of lungs. We investigated real-time lung weight measurements as a reliable method for assessing pulmonary functions in cellular EVLP using a porcine lung model. METHODS: Fifteen pigs were randomly divided into 3 groups: control (no warm ischemia) or donation after circulatory death groups with 60 or 90 min of warm ischemia (n = 5, each). Real-time lung weight gain was measured by load cells positioned at the bottom of the organ chamber. RESULTS: Real-time lung weight gain at 2 h was significantly correlated with lung weight gain as measured on a back table ( R = 0.979, P < 0.01). Lung weight gain in non-suitable cases (n = 6) was significantly higher than in suitable cases (n = 9) at 40 min (51.6 ± 46.0 versus -8.8 ± 25.7 g; P < 0.01, cutoff = +12 g, area under the curve = 0.907). Lung weight gain at 40 min was significantly correlated with PaO 2 /FiO 2 , peak inspiratory pressure, shunt ratio, wet/dry ratio, and transplant suitability at 2 h ( P < 0.05, each). In non-suitable cases, lung weight gain at 66% and 100% of cardiac output was significantly higher than at 33% ( P < 0.05). CONCLUSIONS: Real-time lung weight measurement could potentially be an early predictor of pulmonary function in cellular EVLP.


Assuntos
Transplante de Pulmão , Animais , Circulação Extracorpórea/métodos , Isquemia , Pulmão , Transplante de Pulmão/métodos , Perfusão/métodos , Suínos
3.
Artif Organs ; 46(8): 1522-1532, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35230734

RESUMO

BACKGROUND: Thermography is a noninvasive technology to detect low temperatures in poorly circulated areas. In ex vivo lung perfusion (EVLP), lungs are rewarmed to body temperature during the initial 1 h. Currently, the effect of graft thermal changes during the rewarming phase on pulmonary function is unknown. In this study, we evaluated the correlation of lung surface temperature with physiological parameters, wet/dry ratio, and transplant suitability in Lund-type EVLP. METHODS: Fifteen pigs were divided into three groups: control group (no warm ischemia) or donation after circulatory death groups with 60 or 90 min of warm ischemia (n = 5, each). Thermal images of the lower lobes were continuously collected from the bottom of an organ chamber using infrared thermography throughout EVLP. RESULTS: At 8 min, lung surface temperatures of nonsuitable cases were significantly lower than in suitable cases (25.1 ± 0.6 vs. 27.8 ± 1.2°C, p < 0.001), while there was no difference in lung surface temperatures between the two groups at 0-4 min and 12-120 min. There was a significant negative correlation between lung surface temperatures at 8 min and wet/dry ratio at 2 h in the lower lobes (R = -0.769, p < 0.001, cutoff = 26°C, area under the curve = 1.0). A lung surface temperature of <26°C was significantly correlated with poor pulmonary function and transplant nonsuitability. CONCLUSION: A lung surface temperature of ≥26°C at 8 min is a good early predictor of transplant suitability in cellular EVLP and might be applicable in clinical EVLP.


Assuntos
Transplante de Pulmão , Animais , Isquemia , Pulmão/fisiologia , Transplante de Pulmão/efeitos adversos , Transplante de Pulmão/métodos , Perfusão/métodos , Reperfusão/métodos , Suínos , Termografia
4.
Biomed Opt Express ; 13(1): 328-343, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35154874

RESUMO

Ex vivo lung perfusion (EVLP) is an emerging tool to evaluate marginal lungs in lung transplantation. However, there is no objective metric to monitor lobular regional oxygenation during EVLP. In this study, we developed oxygen saturation (SaO2) imaging to quantitatively assess the regional gas exchange potential of the lower lobes. Ten porcine lungs were randomly divided into control and donation after circulatory death (DCD) groups (n = 5, each). Lungs were perfused in cellular EVLP for 2 h, and multispectral images were continuously collected from the dorsal sides of the lower lobes. We examined whether lower lobe SaO2 correlated with PaO2/FiO2 (P/F) ratios in lower pulmonary veins (PV). The wet/dry ratio in lower lobes was measured and Monte Carlo simulations were performed to investigate the method's feasibility. There was a significant correlation between lower lobe SaO2 and the P/F ratio in lower PV (r = 0.855, P < 0.001). The DCD group was associated with lower SaO2 and higher wet/dry ratio than the control group (P < 0.001). The error of estimated SaO2 was limited according to Monte Carlo simulations. The developed technology provides a noninvasive and regional evaluative tool of quantitative lobular function in EVLP.

5.
J Artif Organs ; 25(3): 195-203, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35088287

RESUMO

Plasma skimming can exclude red blood cells from high shear regions in the gaps formed by hydrodynamic bearings in rotary blood pumps. We investigated the effect of the gap size and groove design on the plasma skimming efficiency. Spiral groove bearings (SGBs) were installed into a specially designed test rig for in vitro experiments performed using human blood. The measured gap between the ridges of the bearing and the rotor surface was 17-26 µm at a flow rate of 150 ml/min and a rotor speed of 2400 rpm. Three different patterns of SGBs were designed (SGB-0, SGB-30, and SGB-60) with various degrees of the circumferential component. The hematocrit measured by a high-speed camera was compared with the hematocrit in the circuit, and the plasma skimming efficiency for the three bearing patterns was evaluated at hematocrits of 20%, 25%, and 30%. SGB-60, which had the strongest circumferential component, provided the best plasma skimming efficiency. When the gap size was less than 20 µm, the red blood cells in the gaps between the ridges of the bearing and rotor surface reduced significantly and the efficiency became higher than 90%. The gap size had the strongest effect on producing a significant plasma skimming. The plasma skimming efficiency can be significantly improved by optimizing the bearing gap size and groove design, which facilitates the further development of SGBs for use in applications such as rotary blood pumps.


Assuntos
Circulação Assistida , Coração Auxiliar , Desenho de Equipamento , Eritrócitos , Hematócrito , Hemólise , Humanos , Hidrodinâmica
6.
ASAIO J ; 68(9): 1128-1134, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34967782

RESUMO

Acquired von Willebrand syndrome (AVWS), characterized by reduced von Willebrand factor (VWF) large multimers, has recently been implicated as the principal mechanism underlying bleeding in patients implanted with left ventricular assist devices (LVADs). Hematological severity of AVWS varies among patients, even if an identical device is implanted. We investigated whether this diversity in hematological severity is due to individual variability in VWF fragility, according to responses to incremental shear stress. Whole-blood samples were sheared at 20,000-40,000 s -1 shear rate, an index of shear stress, using a custom-made shear stressor that could generate shear stress compatible with that produced by an LVAD. The degree of VWF large multimers degradation was evaluated using the VWF large multimer index. A significant inverse correlation was observed between the VWF large multimer index and LVAD-compatible magnitudes of shear stress: the VWF large multimer indices were 68.5 ± 18.3, 48.0 ± 13.9, 33.9 ± 12.1, 23.7 ± 7.9, and 18.7% ± 8.7% at 20,000, 25,000, 30,000, 35,000, and 40,000 s -1 of shear rates, respectively ( P < 0.0001). Furthermore, experimental VWF large multimer index values were compatible with those derived from patients with implanted LVADs (median; 28.9%). Finally, reduction in the VWF large multimer index corresponding to shear stress showed individual variation. We demonstrated that the combined use of a novel high shear stress loading device and quantitative evaluation of VWF large multimers may predict risk of bleeding before LVAD implantation.


Assuntos
Coração Auxiliar , Doenças de von Willebrand , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Humanos , Estresse Mecânico , Doenças de von Willebrand/etiologia , Fator de von Willebrand/metabolismo
7.
Int J Artif Organs ; 45(4): 431-437, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34661490

RESUMO

Low-flow blood pumps rated under 1 L/min are emerging for new medical applications, such as hemofiltration in acute use. In those pumps, platelet adhesion and aggregation have to be carefully considered because of clogging risk in the filter part. To find an acceptable hemocompatibility that can be applied to low-flow centrifugal blood pump design, the platelet aggregation index, clogging on a micromesh filter, and the hemolysis index were investigated using a low-flow blood pump designed for hemofiltration use. We conducted circulation testing in vitro using fresh porcine blood and two centrifugal pumps with different impeller inlet shapes. The Negative Log Platelet Aggregation Threshold Index (NL-PATI), which reflects the ability of residual platelets to aggregate, and flow rate were measured during reflux for 60 min, and the Normalized Index of Hemolysis (NIH (g/20 min)) was calculated. In addition, blood cell clogging after reflux was observed on the micromesh filter by SEM, and the adhesion rate was calculated. Our results showed that the platelet clogging on the micromesh filter occurred when the average NL-PATI was greater than 0.28 and the average NIH (g/20 min) was greater than 0.01. In contrast, platelet clogging on the micromesh was suppressed when NL-PATI was less than 0.17 and the NIH (g/20 min) was less than 0.003. These values might be used as acceptable hemocompatibility of low-flow centrifugal blood pumps with suppressed platelet clogging for hemofiltration pumps.


Assuntos
Plaquetas , Coração Auxiliar , Animais , Coração Auxiliar/efeitos adversos , Hemólise , Agregação Plaquetária , Testes de Função Plaquetária , Suínos
8.
Int J Artif Organs ; 44(10): 687-693, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34058917

RESUMO

Blood pumps are often used for hemofiltration in patients with renal failure. To design effective centrifugal blood pumps for hemofiltration, it is important to suppress clogging caused by platelet aggregation. However, the optimal conditions for conducting anti-platelet aggregation tests in vitro have not yet been established. This study aimed to quantify the effect of the shear loading value and shear loading time on platelet aggregation and determine the optimal conditions for anti-platelet aggregation testing in vitro. To quantitatively evaluate platelet aggregation in terms of the negative logarithm-platelet aggregation threshold index (NL-PATI), which reflects the propensity of residual platelets to aggregate after shear loading, the following parameters were examined: blood collection method (collected from porcine vein using a syringe or collected from a slaughterhouse), type of anticoagulant (sodium citrate or heparin), shear rate, and shear time. The results showed that platelet aggregation in porcine blood increased under a high shear load applied at shear rates of approximately 20,000 s-1 or higher for 30 s. Platelet aggregation propensity was 2-3 times higher in heparin-anticoagulated blood than in sodium citrate-anticoagulated blood. Moreover, platelet aggregation was 1.5-2 times more in blood collected from the slaughterhouse than in syringe-collected blood. Testing with an integrated shear time of 30 s or less in relation to the total blood volume may be effective for conducting in vitro circulation experiments using hemofiltration blood pumps. The conditions established in this study may be useful for hemocompatibility testing of cardiovascular devices based on NL-PATI.


Assuntos
Plaquetas , Agregação Plaquetária , Animais , Heparina , Humanos , Técnicas In Vitro , Testes de Função Plaquetária , Estresse Mecânico , Suínos
9.
J Artif Organs ; 24(2): 157-163, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33428006

RESUMO

We have developed a hydrodynamically levitated centrifugal blood pump. In the blood pump having hydrodynamic bearings, the narrow bearing gap has a potential for high hemolysis. The purpose of the this study is to improve hemolysis performance in a hydrodynamically levitated centrifugal blood pump by optimizing a shroud size. The impeller was levitated passively at the position where the thrust forces acting on the impeller were balanced. We focused on a size of a bottom shroud with a hydrodynamic bearing that could change the bottom hydrodynamic force to balance the thrust force at the wide bearing gap for reducing hemolysis. Five test models with various shroud size were compared: 989 mm2 (HH-10.5), 962 mm2 (HH-12), 932 mm2 (HH-13.5), 874 mm2 (HH-16), and 821 mm2 (HH-18). A numerical analysis was first performed to estimate the bearing gaps in the test model. The bearing gaps were then measured to validate the numerical analysis. Finally, an in vitro hemolysis test was performed. The numerical analysis revealed that the HH-13.5 model had the widest bearing gap of 129 µm. In the measurement test, the estimation error for the bearing gap was less than 10%. In the hemolysis test, the HH-13.5 model achieved the lowest hemolysis level among the five models. The present study demonstrated that the numerical analysis was found to be effective for determining the optimal should size, and the HH-13.5 model had the optimal shroud size in the developed hydrodynamically levitated centrifugal blood pump to reduce hemolysis.


Assuntos
Coração Auxiliar , Hemólise , Centrifugação , Desenho de Equipamento , Humanos , Hidrodinâmica , Desenho de Prótese
10.
J Artif Organs ; 24(2): 126-134, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33113050

RESUMO

This work investigates the plasma skimming effect in a spiral groove bearing within a hydrodynamically levitated centrifugal blood pump when working with human blood having a hematocrit value from 0 to 40%. The present study assessed the evaluation based on a method that clarified the limitations associated with such assessments. Human blood was circulated in a closed-loop circuit via a pump operating at 4000 rpm at a flow rate of 5 L/min. Red blood cells flowing through a ridge area of the bearing were directly observed using a high-speed microscope. The hematocrit value in the ridge area was calculated using the mean corpuscular volume, the bearing gap, the cross-sectional area of a red blood cell, and the occupancy of red blood cells. The latter value was obtained from photographic images by dividing the number of pixels showing red blood cells in the evaluation area by the total number of pixels in this area. The plasma skimming efficiency was calculated as the extent to which the hematocrit of the working blood was reduced in the ridge area. For the hematocrit in the circuit from 0 to 40%, the plasma skimming efficiency was approximately 90%, meaning that the hematocrit in the ridge area became 10% as compared to that in the circuit. For a hematocrit of 20% and over, red blood cells almost completely occupied the ridge. Thus, a valid assessment of plasma skimming was only possible when the hematocrit was less than 20%.


Assuntos
Eritrócitos , Coração Auxiliar , Circulação Assistida , Centrifugação , Hematócrito , Hemólise , Humanos , Hidrodinâmica , Desenho de Prótese
11.
Int J Artif Organs ; 44(8): 565-573, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33300399

RESUMO

INTRODUCTION: Real-time, non-invasive monitoring of thrombus formation in extracorporeal circuits has yet to be achieved. To address the challenges of conventional optical thrombus detection methods requiring large devices that limit detection capacity, we developed a micro-optical thrombus sensor. METHODS: The proposed micro-optical thrombus sensor can detect the intensity of light scattered by blood at wavelengths of 660 and 855 nm. Two thrombus sensors were installed on in vitro circuit: one at the rotary blood pump and one at a flow channel. To evaluate the variation in the ratio of incident light intensity at each wavelength of the two sensors, Rfluct (for 660 nm) and Ifluct (for 855 nm) were defined. Using fresh porcine blood as a working fluid, we performed in vitro tests of haematocrit (Hct) and oxygen saturation (SaO2) variation and thrombus detection. Thrombus tests were terminated after Rfluct or Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. RESULTS: In all three thrombus detection tests, Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. After the tests, thrombus formation was confirmed in the pump, and there was no thrombus in the flow channel. The results indicate that Ifluct is an effective parameter for identifying the presence of a thrombus. CONCLUSION: Thrombus detection in an extracorporeal circuit using the developed micro-optical sensors was successfully demonstrated in an in vitro test.


Assuntos
Trombose , Animais , Hematócrito , Suínos , Trombose/diagnóstico por imagem
12.
Artif Organs ; 44(6): 594-603, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31904107

RESUMO

The use of contactless support technology for the impeller has led to an increase in the durability of ventricular assist devices (VADs), and these have been in clinical use worldwide. However, pump thrombosis and stroke are still issues to be solved. We have developed a method for detecting the thrombosis in a magnetically levitated blood pump without the need for additional sensors or other equipment. In the proposed method, a sinusoidal current is applied to the electromagnets used for the magnetic bearing, resulting in vibration of the impeller. The phase difference between the current and displacement of the impeller increases with pump thrombosis. First, we describe the principle by which the pump thrombosis is detected. Pump thrombosis reduces the narrowest fluid gap in the pump and this gives rise to a change in the phase difference. Second, we report on experiments in which we changed the narrowest fluid gap using oriented polypropylene tape and showed that decreasing the narrowest fluid gap resulted in an increase in phase difference. For these experiments, the measurements were repeated three times for each condition. Third, we examine the relationship between the pump thrombosis and the phase difference evaluated by observations of the underside of the impeller when operating the pump with porcine blood. Since light was unable to penetrate the blood layer, the erythrocytes were removed for this observation. Only one observation was made. The results showed the phase difference rapidly increased at the same moment when the pump thrombosis was observed. This implies the proposed method has the potential to detect the early stages of pump thrombosis. Finally, in vitro experiments to detect thrombosis when using whole porcine blood in the pump were conducted. The experiment was carried out five times. To intentionally form a thrombus inside the pump, the activated clotting time was controlled to be less than 200 s. In every case, the phase difference increased by more than one degree after tens of minutes. Then, the pump was disassembled and a small amount of pump thrombosis was observed. We conclude that real-time diagnosis of pump thrombosis may be realized by measuring the phase difference without the need for additional sensors.


Assuntos
Desenho de Equipamento , Coração Auxiliar/efeitos adversos , Imãs , Trombose/diagnóstico , Animais , Hematócrito , Humanos , Suínos , Trombose/etiologia , Vibração
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 4516-4519, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441355

RESUMO

Thrombus is one of the major problems in ventricular assist devices (VADs). However, method for detecting thrombus in early stage has not been established yet. In this study, we propose an intelligent function that the VAD itself can detect thrombus automatically and alert it to medical staffs. In the proposed method, thrombus formation inside a blood pump is detected by monitoring blood viscosity. This viscosity measurement is performed by using magnetic levitation system for the impeller. Hence, it can be implemented without any additional sensors or mechanisms in principle. For verification of the method, at first, we visualized inside of the pump during thrombus formation with measuring blood viscosity by using erythrocytes removed porcine blood. The result showed that the viscosity of the blood increased as blood coagulation progressed. Then, we conducted in vitro principle verification experiments with three different whole porcine blood. In all experiments, the measured blood viscosity increased and small thrombus was observed inside the pump. From these results, we confirmed that the proposed method has a possibility to detect and predict the thrombus in early stage.


Assuntos
Viscosidade Sanguínea , Coração Auxiliar , Trombose/diagnóstico , Animais , Desenho de Equipamento , Humanos , Magnetismo , Suínos
14.
Biosens Bioelectron ; 112: 79-85, 2018 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-29698811

RESUMO

Red blood cells (RBCs) aggregability AG of coagulating blood in extracorporeal circulation system has been investigated under the condition of pulsatile flow. Relaxation frequency fc from the multiple-frequency electrical impedance spectroscopy is utilized to obtain RBCs aggregability AG. Compared with other methods, the proposed multiple-frequency electrical impedance method is much easier to obtain non-invasive measurement with high speed and good penetrability performance in biology tissues. Experimental results show that, RBCs aggregability AG in coagulating blood falls down with the thrombus formation while that in non-coagulation blood almost keeps the same value, which has a great agreement with the activated clotting time (ACT) fibrinogen concertation (Fbg) tests. Modified Hanai formula is proposed to quantitatively analyze the influence of RBCs aggregation on multiple-frequency electrical impedance measurement. The reduction of RBCs aggregability AG is associated with blood coagulation reaction, which indicates the feasibility of the high speed, compact and cheap on-line thrombus measurement biosensors in extracorporeal circulation systems.


Assuntos
Técnicas Biossensoriais , Agregação Eritrocítica , Fibrinogênio/isolamento & purificação , Trombose/sangue , Coagulação Sanguínea/fisiologia , Espectroscopia Dielétrica , Impedância Elétrica , Eritrócitos/citologia , Circulação Extracorpórea , Fibrinogênio/química , Humanos , Trombose/patologia
15.
Biomed Opt Express ; 9(1): 190-201, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29359096

RESUMO

We developed an optical thrombus sensor for a monopivot extracorporeal centrifugal blood pump. In this study, we investigated its quantitative performance for thrombus detection in acute animal experiments of left ventricular assist using the pump on pathogen-free pigs. Optical fibers were set in the driver unit of the pump. The incident light at the near-infrared wavelength of 810 nm was aimed at the pivot bearing, and the resulting scattered light was guided to the optical fibers. The detected signal was analyzed to obtain the thrombus formation level. As a result, real-time and quantitative monitoring of the thrombus surface area on the pivot bearing was achieved with an accuracy of 3.6 ± 2.3 mm2. In addition, the sensing method using the near-infrared light was not influenced by changes in the oxygen saturation and the hematocrit. It is expected that the developed sensor will be useful for optimal anticoagulation management for long-term extracorporeal circulation therapies.

16.
Artif Organs ; 41(10): 893-903, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28321882

RESUMO

Complications due to pump thrombus remain the weak point of mechanical circulatory support (MCS), such as the use of a left ventricular assist device (LVAD) or extracorporeal membrane oxygenation, leading to poor outcomes. Hyperspectral imaging (HSI) is an effective imaging method using a hyperspectral (HS) camera, which comprises a spectrophotometer and a charge-coupled device camera to discriminate thrombus from whole blood. Animal experiments were conducted to analyze dynamic imaging of thrombus inside a prototype of a hydrodynamically levitated centrifugal blood pump using an HSI system. Six pigs were divided into a venous circulation group (n = 3) and an arterial circulation group (n = 3). Inflow and outflow cannulae were inserted into the jugular veins in the venous circulation group. The latter simulated an LVAD application. To create thrombogenic conditions, pump flow was maintained at 1 L/min without anticoagulation. An image of the bottom surface of the pump was captured by the HS camera every 4 nm over the wavelength range of 608-752 nm. Real-time dynamic images of the inside of the pump were displayed on the monitor. Appearance of an area displaying thrombus was detected within 24 h after the start of the circulation in every experiment. This imaging system also succeeded in determining the origins of pump thrombus: from inside the pump in two cases, and from outside in four cases. Two main possible sources of pump thrombus originating outside the pump were identified on autopsy: wedge thrombus around the inflow cannula; and string-like thrombus at the junction between the pump inlet and circuit tube. The results of this study from close observation of the changing appearance of pump thrombus may contribute to improvements in the safety of extracorporeal MCS.


Assuntos
Oxigenação por Membrana Extracorpórea/efeitos adversos , Coração Auxiliar/efeitos adversos , Imagem Óptica/instrumentação , Trombose/diagnóstico por imagem , Trombose/etiologia , Animais , Desenho de Equipamento , Oxigenação por Membrana Extracorpórea/instrumentação , Imagem Óptica/métodos , Espectrofotometria/instrumentação , Espectrofotometria/métodos , Suínos
17.
Artif Organs ; 40(9): 834-41, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27645394

RESUMO

Continuous optical monitoring of thrombus formation in extracorporeal mechanical circulatory support (EMCS) devices will contribute to safe, long-term EMCS. A clinically applicable optical detector must be able to distinguish among the optical characteristics of oxygen saturation (SaO2 ), hematocrit (Hct), and thrombus formation. In vitro studies of spectral changes at wavelengths from 400 to 900 nm associated with SaO2 , Hct, and thrombus formed around the top pivot bearing of a Gyro C1E3 pump were conducted. Fresh porcine blood anticoagulated with sodium citrate was circulated in a mock circuit using the pump. The SaO2 , Hct, and anticoagulation activity were altered using an oxygenator, autologous plasma, and calcium chlorite injection, respectively. Light from a xenon lamp was guided by an incident fiber perpendicularly fixed on the top bearing. This light was scattered by blood pooled between the male and female pivots. The detection fiber was perpendicularly fixed against the incident fiber, and the side-scattered light was detected and guided to a spectrophotometer. As a result, light at two different wavelengths, 420 and 810 nm, was identified as suitable for thrombus detection because it was negligibly influenced by SaO2 and was able to detect the optical characteristics of fibrin. The light at these two wavelengths responded more quickly to thrombus formation than the inlet or outlet pressure, and flow rate change. The optical changes showed the changes in Hct around the top pivot bearing, which is caused by the reduction in density of fibrin-trapped red blood cells (RBCs) due to the RBCs being swept away by the surrounding blood flow. The proposed method was also able to detect fibrin production by extracting subtle differences in the optical characteristics between the Hct and thrombus formation.


Assuntos
Circulação Extracorpórea/efeitos adversos , Tecnologia de Fibra Óptica/instrumentação , Trombose/diagnóstico , Trombose/etiologia , Animais , Desenho de Equipamento , Circulação Extracorpórea/instrumentação , Hematócrito , Hemodinâmica , Suínos
18.
Artif Organs ; 40(9): 856-66, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27645396

RESUMO

Plasma skimming is a phenomenon in which discharge hematocrit is lower than feed hematocrit in microvessels. Plasma skimming has been investigated at a bearing gap in a spiral groove bearing (SGB), as this has the potential to prevent hemolysis in the SGB of a blood pump. However, it is not clear whether plasma skimming occurs in a blood pump with the SGB, because the hematocrit has not been obtained. The purpose of this study is to verify plasma skimming in an SGB of a centrifugal blood pump by developing a hematocrit measurement method in an SGB. Erythrocyte observation using a high-speed microscope and a bearing gap measurement using a laser confocal displacement meter was performed five times. In these tests, bovine blood as a working fluid was diluted with autologous plasma to adjust the hematocrit to 1.0%. A resistor was adjusted to achieve a pressure head of 100 mm Hg and a flow rate of 5.0 L/min at a rotational speed of 2800 rpm. Hematocrit on the ridge region in the SGB was measured using an image analysis based on motion image of erythrocytes, mean corpuscular volume, the measured bearing gap, and a cross-sectional area of erythrocyte. Mean hematocrit on the ridge region in the SGB was linearly reduced from 0.97 to 0.07% with the decreasing mean bearing gap from 38 to 21 µm when the rotational speed was changed from 2250 to 3000 rpm. A maximum plasma skimming efficiency of 93% was obtained with a gap of 21 µm. In conclusion, we succeeded in measuring the hematocrit on the ridge region in the SGB of the blood pump. Hematocrit decreased on the ridge region in the SGB and plasma skimming occurred with a bearing gap of less than 30 µm in the hydrodynamically levitated centrifugal blood pump.


Assuntos
Circulação Assistida/instrumentação , Eritrócitos/citologia , Hematócrito/métodos , Algoritmos , Animais , Bovinos , Centrifugação/instrumentação , Desenho de Equipamento , Índices de Eritrócitos , Hidrodinâmica , Microvasos/fisiologia
19.
J Artif Organs ; 19(4): 322-329, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27370698

RESUMO

An impeller the same geometry as the impeller of a commercial monopivot cardiopulmonary bypass pump was manufactured using 3D printing. The 3D-printed impeller was integrated into the pump casing of the commercially available pump to form a 3D-printed pump model. The surface roughness of the impeller, the hydraulic performance, the axial displacement of the rotating impeller, and the hemolytic properties of the 3D-printed model were measured and compared with those of the commercially available model. Although the surface roughness of the 3D-printed model was significantly larger than that of the commercially available model, the hydraulic performance of the two models almost coincided. The hemolysis level of the 3D-printed model roughly coincided with that of the commercially available model under low-pressure head conditions, but increased greatly under high-pressure head conditions, as a result of the narrow gap between the rotating impeller and the pump casing. The gap became narrow under high-pressure head conditions, because the axial thrust applied to the impeller increased with increasing impeller rotational speed. Moreover, the axial displacement of the rotating impeller was twice that of the commercially available model, confirming that the elastic deformation of the 3D-printed impeller was larger than that of the commercially available impeller. These results suggest that trial models manufactured by 3D printing can reproduce the hydraulic performance of the commercial product. However, both the surface roughness and the deformation of the trial models must be considered to precisely evaluate the hemolytic properties of the model.


Assuntos
Coração Auxiliar , Impressão Tridimensional , Ponte Cardiopulmonar , Desenho de Equipamento , Hemólise , Hemorreologia , Humanos , Pressão
20.
Artif Organs ; 40(6): E89-E101, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27097844

RESUMO

The effect of the flow path geometry of the impeller on the lift-off and tilt of the rotational axis of the impeller against the hydrodynamic force was investigated in a centrifugal blood pump with an impeller supported by a single-contact pivot bearing. Four types of impeller were compared: the FR model with the flow path having both front and rear cutouts on the tip, the F model with the flow path having only a front cutout, the R model with only a rear cutout, and the N model with a straight flow path. First, the axial thrust and the movement about the pivot point, which was loaded on the surface of the impeller, were calculated using computational fluid dynamics (CFD) analysis. Next, the lift-off point and the tilt of the rotational axis of the impeller were measured experimentally. The CFD analysis showed that the axial thrust increased gently in the FR and R models as the flow rate increased, whereas it increased drastically in the F and N models. This difference in axial thrust was likely from the higher pressure caused by the smaller circumferential velocity in the gap between the top surface of the impeller and the casing in the FR and R models than in the F and N models, which was caused by the rear cutout. These results corresponded with the experimental results showing that the impellers lifted off in the F and N models as the flow rate increased, whereas it did not in the FR and R models. Conversely, the movement about the pivot point increased in the direction opposite the side with the pump outlet as the flow rate increased. However, the tilt of the rotational axis of the impeller, which oriented away from the pump outlet, was less than 0.8° in any model under any conditions, and was considered to negligibly affect the rotational attitude of the impeller. These results confirm that a rear cutout prevents lift-off of the impeller caused by a decrease in the axial thrust.


Assuntos
Circulação Assistida/instrumentação , Hidrodinâmica , Engenharia Biomédica , Simulação por Computador , Desenho de Equipamento , Humanos